BMW N52 Water Pump and Thermostat Replacement
The N52 electric coolant pump sits on the front of the engine, bolted through the thermostat housing. You reach it from below after the front underbody panel is off. This guide covers pump and thermostat replacement: drain, renew hardware, refill, and bleed with the electric-pump vent routine.
Fits US N52 cars
E90/E91/E92/E93 328i (2007 to 2013) first, then E82/E88 128i, E60/E61 528i, E83 X3 3.0si and xDrive30i, E70 X5 xDrive30i, E85/E86/E89 Z4, F10 528i (2011), and F25 X3 xDrive28i (2011). Use the part rows below for your chassis; E70 X5 pump OE varies.
- E-chassis pump torque
- 10 Nm + 90°
- Electric bleed run
- approx 12 min
- Thermostat housing
- 8 Nm
Before you start
Work on a cooled engine only. Catch drained coolant and dispose of it properly. Plan fresh coolant for the refill. The N52 crankcase is magnesium: use aluminum pump and bracket fasteners only, never steel substitutes. Keep the expansion tank cap closed during the electric-pump vent run after refill.
What you replace
Electric coolant pump, E-chassis and most US N52 cars
11 51 7 586 925 (11517586925)
Superseded 11 51 7 586 924 (11517586924). E90/E91/E92/E93 328i, E82/E88 128i, E60/E61 528i, E83 X3, E85/E86/E89 Z4: this line.
Pierburg electric water pumpElectric coolant pump, E70 X5 xDrive30i (catalog history)
E70 N52N earlier line: 11 51 7 568 595 (11517568595). Current line: 11 51 9 894 484 (11519894484) (supersedes 11 51 7 568 595 (11517568595)). Also listed: 11 51 7 586 925 (11517586925). Send us your VIN and we'll send yours.
Electric coolant pump, F10 528i and F25 X3 xDrive28i N52N
11 51 8 635 092 (11518635092)
Superseded 11 51 7 583 836 (11517583836).
Pierburg F-chassis electric water pumpThermostat, E-chassis and most US N52 cars
11 53 7 549 476 (11537549476)
Superseded 11 53 7 544 788 (11537544788). Same E-chassis cars as the pump row above.
Mahle thermostatThermostat, E70 X5 xDrive30i N52N
11 53 7 550 172 (11537550172)
Water pump aluminum screw set
11 51 0 392 553 (11510392553)
Superseded 11 51 0 422 128 (11510422128). Replace water pump to crankcase screws every pump job.
Outer Torx screw with washer M8x20 (pump diagram)
12 52 7 557 037 (12527557037)
Bracket to crankcase screws, hose clamps, drain plug sealing rings
Replace bracket coolant hoses to crankcase screws, disturbed hose clamps, drain plug sealing rings, and every aluminum screw you release on the pump and housing.
Fresh coolant for refill
Fill to capacity after thermostat or pump work. Coolant capacity and mix ratio: send us your VIN and we'll send yours.
Out in this order
- Drain coolantexpansion tank, radiator, thermostat hose
- Front underbody protectionunder-engine access
- AWD reinforcement platexDrive only
- Pump plug connectioncover terminals
- Coolant hose (2)clamp torque on refit
- Thermostat housingthermostat housing screws
- Coolant hose (5)second pump hose
- Electric coolant pumpnew pump-to-crankcase screws
- Refill and warmrecheck level
- Bleed with vent routinepedal and electric pump run
Steps, torque values and part rules come from BMW's repair instructions for electric coolant pump and thermostat replacement on the N52. Part numbers come from BMW's parts catalog up to 2020. Check yours by VIN.

- Electric coolant pump
- Thermostat housing
- Coolant hose at the housing
- Water pump to crankcase screws
Tools
Drain pans and shop towels
Catch coolant; clean spills so the floor is not slippery.
Safety goggles and gloves
Torque wrench with angle gauge
Battery charger
Jack stands or lift, trim tools
Underbody protection comes off from below. Do not work under a jack alone.
Steps
-
Drain the cooling system
Drain coolant from the expansion tank, the radiator drain, and the thermostat hose into your pans before you open the pump area.
Caution: scald risk on a hot engine. Open the expansion tank cap only after the engine has cooled. Do not reuse drained lifetime coolant when you renew cooling parts.
-
Remove underbody protection
Remove the front underbody protection so you can reach the electric coolant pump on the front of the engine from underneath.
-
AWD reinforcement plate
xDrive (AWD): remove BMW's reinforcement plate under the engine before pump hardware comes off. RWD: skip this step.
-
Unplug the pump

- Electric coolant pump plug connection
- Connector wiring loom
Disconnect the electric coolant pump plug connection and keep the terminals covered while coolant is open.
-
Lower coolant hose
Disconnect coolant hose (2) at the pump and replace the clamp if you disturbed it.
-
Loosen thermostat housing
Release the thermostat housing screws, lift the housing, and lay the thermostat assembly aside where hoses stay unstressed while the pump comes off.
Caution: Replace bracket coolant hoses to crankcase screws on reinstall.
-
Upper coolant hose
Disconnect coolant hose (5) at the pump and replace the clamp if you disturbed it.
-
Release pump screws
Release the water pump to crankcase screws with aluminum hardware only; do not force or pry the pump.
Caution: New pump-to-crankcase screws every time. Drop or impact on the pump means renew it, even if it looks fine.
-
Lift out the pump
Remove the electric coolant pump straight out without impact or levering.
-
Reused pump check
If you reinstall the old pump, rotate the impeller once by hand before you bolt it up. Skip this when the pump is new.
-
Install pump and housing
Install the pump and thermostat in reverse order at the jointing torques in the Torque specs panel.
-
Top up and warm
Top up coolant, warm the engine, and recheck the level before you run the electric-pump bleed.
-
Bleed with vent routine
Bleed the cooling system with the N52 electric-pump vent procedure after any pump or thermostat work.
- Connect a battery charger. Ignition on, engine must not start. Heater on max temp, fan on lowest.
- Press the accelerator to the floor for 10 seconds, then let the electric pump run for approx 12 minutes. Keep the expansion tank cap closed during the run.
- Top up to MAX after venting.
- Repeat after removing the key and waiting approx 3 minutes for a DME reset if air remains.
- Check level with coolant at max 30 degrees C.
Caution: cooling system vent screw tightening: send us your VIN and we'll send yours.
-
Thermostat-only path
Thermostat-only service: disconnect the hoses and plug, release the thermostat housing screws at 8 Nm, remove the thermostat, then fill the system and check for leaks without removing the pump.
Torque specs
Read the full guide free
Two quick answers open the rest of the steps.
Now find the part.